Evaluation of Stress Distribution in Implant Body and Surrounding Bone with and without Splinting—A Three-Dimensional Finite Element Analysis: An In Vitro Study

Keywords : finite element analysis, implant, splinting, stress distribution

Citation Information : Evaluation of Stress Distribution in Implant Body and Surrounding Bone with and without Splinting—A Three-Dimensional Finite Element Analysis: An In Vitro Study. 2022; 10 (1):15-20.

DOI: 10.1055/s-0042-1749464

License: CC BY-NC-ND 4.0

Published Online: 02-06-2022

Copyright Statement:  © 2022. Bhojia Dental College and Hospital affiliated to Himachal


Abstract

Introduction This study was undertaken to evaluate the pattern of stress distribution in implant body and surrounding bone with and without splinting of implant prostheses when subjected to occlusal loading, using the finite element analysis. Methods The geometric models of implant and mandibular bone were generated. Two models were created in accordance with the need of the study. The first model was given a two implant in the first mandibular molar and second premolar with splinted prosthesis. Then, second model was given two such implants in the same region but without splinting the prosthesis. Forces of 100 N and 50 N were applied axially and buccolingually, respectively. Results The maximum von Mises stress values with axial force of the implant splinted prosthesis were observed to be 4.21 MPa for cortical bone, 0.88 MPa for cancellous bone, and 10.592 MPa for implant body. The maximum von Mises stress values with buccolingual force of the implant splinted prosthesis were observed to be 9.08 MPa for cortical bone, 1.33 MPa for cancellous bone, and 30.08 MPa for implant body. The maximum von Mises stress values with axial force of the implant nonsplinted prosthesis were observed to be 4.51 MPa for cortical bone, 0.91 MPa for cancellous bone, 13.18 MPa for implant body. The maximum von Mises stress values with buccolingual force of the implant nonsplinted prosthesis were observed to be 9.52 MPa for cortical bone, 1.91 MPa for cancellous bone, 35.04 MPa for implant body. Conclusion The maximum stresses were transferred more to the implant body than to the bone in both the splinted and nonsplinted implant prostheses. The maximum von Mises stresses were observed on nonsplinted implant prostheses, so splinting implant prostheses led to lower stress in the implant body and surrounding bone.


PDF Share
  1. Misch: Contemporary Implant Dentistry. 3rd edition. Missouri: Mosby Inc; 2008; Rationale of implants: 3–18
  2. Finite element studies on the role of mechanicCal loading in bone response around oral implants. Meccanica 2002;37:441–451
  3. Indications for splinting implant restorations. J Oral Maxillofac Surg 2005;63(11):1642–1652
  4. The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: a finite element analysis. Eur J Dent 2015;9(03):311–318
  5. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent 2001; 85(06):585–598
  6. Analysis of loadtransfer and stress distribution by splinted and unsplinted implant-supported fixed cemented restorations. J Oral Rehabil 2010;37(09):658–662
  7. Effect of splinting and interproximal contact tightness on load transfer by implant restorations. J Prosthet Dent 2002;87(05):528–535
  8. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. Int J Oral Maxillofac Implants 2002;17(02):231–237
  9. Comparison of strains for splinted and nonsplinted implant prostheses using three-dimensional image correlation. Int J Oral Maxillofac Implants 2010;25(05):953–959
  10. Finite element analysis of stress distribution with splinted and nonsplinted maxillary anterior fixed prostheses supported by zirconia or titanium implants. Int J Oral Maxillofac Implants 2013;28 (01):e27–e38
  11. Threedimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support, prosthesis type, and loading during function. J Prosthet Dent 1996;76(06):633–640
  12. Influence of cortical bone quality on stress distribution in bone around dental implant. Dent Mater J 2005;24(02):219–224
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.