Dental Journal of Advance Studies

Register      Login

VOLUME 2 , ISSUE 3 ( September-December, 2014 ) > List of Articles

CASE REPORT

Overdenture Utilizing Access Post System - A Case Report

Sumit Aggarwal, Shalu Jain

Keywords : Access post, Attachment, Overdenture

Citation Information : Aggarwal S, Jain S. Overdenture Utilizing Access Post System - A Case Report. 2014; 2 (3):162-165.

DOI: 10.1055/s-0038-1672004

License: NA

Published Online: 12-05-2023

Copyright Statement:  NA


Abstract

Overdenture treatment precludes the inevitability of “floating plastic” in edentulous mouths. It is an effective and versatile way of restoring teeth and improving facial contours. This case report presents an insight on utilizing a new innovative ‘Access post overdenture’ system which provides more advantages than any other passive overdenture post. It's patented thick walled hollow tube design, stabilizing flange and undercuts of the shank offer strength, retention and stability with the added insurance policy of retreatability. The access post overdenture fabricated was well retentive and esthetic serving as a conservative approach to root preservation.


PDF Share
  1. Brewer AA, Morrow RM. Overdentures. 2nd ed. St Louis: CV Mosby; 1980.
  2. Cohen BI, Deutsch AS, Musikant BL. Cyclic fatigue testing of six endodontic post systems. J Prosthodont 1993;2(1):28-32.
  3. Rovatti L, Dallari A, Mason PN. A new system of endodontic retention. Journal of Attualita Dentale 1994;18.
  4. Jain DC, Hegde V, Aparna I, Dhanasekar B. Overdenture with access post system: A clinical report. Ind J Dent Res 2011;22(2):359-361.
  5. Ivy SS, Robert MM. Overdentures. Principle and procedures. Dent Clin North Am 1996;40(1):169-194.
  6. Cohen BI, Condos S, Deutsch AS, Musikant BL. Cyclic fatigue testing of seven endodontic post systems. J Dent Res 1993;72:305.
  7. Cohen BI, Pagnillo MK, Condos S, Musikant BL, Deutsch AS. Post removal using a thick-walled hollow tube post design. Oral Health 1994;84(11):15-22.
  8. Cohen BI, Musikant BL, Deutsch AS. Comparison of the retentive properties of two hollow post systems to a solid post design. J Prosthet Dent 1993;70(3):234-238.
  9. Leung, T, Preiskel HW. Retention profiles of stud-type precision attachments. Int J Prosthodont 1991;4(2):175-179.
  10. Cohen BI, Pagnillo MK, Condos S, Deutsch AS. Comparative study of two precision overdenture attachment designs. J Prosthet Dent 1996;76(2):145-152.
  11. Sunil D, Neha D. Access post overdenture – a solution for challenging edentulous situation. Bangladesh Journal of Medical Science 2011;10(3): 203-205.
  12. Epstein DD, Epstein PL, Cohen BI, Pagnillo MK. Comparison of the retentive properties of six prefabricated post overdenture attachment systems. J Prosthet Dent 1999;82(5):579-584.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.