Abstract

Aim: The aim of this study was to evaluate the apical transportation, centering ability and cyclic fatigue resistance of Hero shaper, Twisted file, Hyflex file and RACE rotary file systems. Methods: Mesiobuccal roots of eighty maxillary molars were divided into four groups and instrumented with Hero shaper, Twisted file, Hyflex file and RACE rotary file systems with a final apical size being 25/.04. Apical deviation was assessed by the radiographic platform method that enables obtaining superimposed images of the first and last instrument used in root canal preparation in the same radiograph. Apical transportation was measured in millimeters with the aid of the AUTOCAD 2008 software. Forty canals were sectioned at 7mm from the apex and stereomicroscopic Images were taken at 6x magnification before and after instrumentation for evaluation of centering ability. The cyclic fatigue testing was conducted with the instrumentrotating freely at angles of curvature of 45 degree. Total 10 instruments were tested in each group. The instruments were rotated at 400rpm using the X-smart motor (Dentsply, Maillefer) until fracture occurred. Results: There was no statistically significant difference between the four groups in apical transportation and centering ability whereas twisted files showed the maximum cyclic fatigue resistance. Conclusion: The different rotary file systems provided minimum canal transportation and the twisted file performed significantly better in terms of cyclic fatigue resistance.


PDF Share
  1. Ugur Inan, and Cumhur Aydin. Comparison of cyclic fatigue resistance of three different rotary nickel-titanium instruments designed for retreatment. J Endod 2012;38: 108-111
  2. Alanna Junaid, Laila Gonzales Freire, Carlos Eduardo da Silveira Bueno, Isabel Mello, and Rodrigo Sanches Cunha. Influence of Single-file Endodontics on Apical Transportation in Curved Root Canals: An Ex Vivo Micro–Computed Tomographic Study. J Endod 2014;40:717-720
  3. Brandon Yamamura, Timothy C. Cox, Belal Heddaya, Natasha M. Flake, James D. Johnson and Avina Paranjpe. Comparing Canal Transportation and Centering Ability of Endo Sequence and Vortex Rotary Files by Using Micro–Computed Tomography. J Endod 2012;38:1121-1125
  4. Kadir T. Ceyhanli, Necdet Erdilek, Ilkan Tatar, and Bekir Çetintav. Comparative micro-computed tomography evaluation of apical root canal transportation with the use of ProTaper, RaCe and Safesider systems in human teeth. Aust Endod J 2014;40: 12–16
  5. Yong Gao, Vincent Shotton, Kevin Wilkinson, Greg Phillips, and William Ben Johnson. Effects of Raw Material and Rotational Speed on the Cyclic Fatigue of ProFile Vortex Rotary Instruments. J Endod 2010; 36:1205-1209
  6. Gaurav Garg, Sanjay Miglani, Seema Yadav, Sangeeta Talwar. A Comparative Evaluation of Cyclic Fatigue Resistance of Two Rotary Nickel - Titanium Endodontic Systems - An In Vitro Study. Endodontology 2008;22-26
  7. Richard Gergi, Joe Abou Rjeily, Joseph Sader, and Alfred Naaman. Comparison of Canal Transportation and Centering Ability of Twisted Files, Pathfile-ProTaper System, and Stainless Steel Hand K-Files by Using Computed Tomography. J Endod 2010;36:904-907
  8. Nilav Bhagabati, Seema Yadav and Sangeeta Talwar. An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel- Titanium Rotary Instruments. J Endod 2012;38:515-518
  9. O. A. Peters, A. K. Gluskin, R. A. Weiss and J. T. Han. An in vitro assessment of the physical properties of novel Hyflex nickel–titanium rotary instruments. Int Endod J 2012; 1-8
  10. Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-67.
  11. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root. J Endod 2000;26:210-6.
  12. Marc Garcýa, Fernando Duran-Sindreu, Montse Mercade, Rufino Bueno, and Miguel Roig. A Comparison of Apical Transportation between ProFile and RaCe Rotary Instruments. 2012; 38:990-992
  13. Young JM, Van Vliet KJ. Predicting in vivo failure of pseudoelastic NiTi devices under low cycle, high amplitude fatigue. J Biomed Mater Res B Appl Biomater 2005;72:17–26.
  14. Frank C. Setzer and Christian P. Bohme. Influence of Combined Cyclic Fatigue and Torsional Stress on the Fracture Point of Nickel-Titanium Rotary Instruments. 2013; 39(1):133-137
  15. Fife D, Gambarini G, Britto LR. Cyclic fatigue testing of ProTaper NiTi rotary instruments after clinical use. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2004;97:251–6.
  16. Yao JH, Schwartz SA, Beeson TJ. Cyclic fatigue of three types of rotary nickel-titanium files in a dynamic model. J Endod 2006;32:55–7.
  17. Lopes HP, Ferreira AA, Elias CN. Influence of rotational speed on the cyclic fatigue of rotary nickel-titanium endodontic instruments. J Endod 2009;35:1013–6.
  18. Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel-titanium endodontic instruments. J Endod 1997; 23:77–85
  19. N. M. Grande1, G. Plotino, R. Pecci, R. Bedini, V. A. Malagnino & F. Somma. Cyclic fatigue resistance and threedimensional analysis of instruments from two nickel–titanium rotary systems. Int Endod J 2006;39:755-763
  20. L. Testarelli, N.M. Grande, G. Plotino, M. Lendini, G. Pongione, G. De Paolis, F. Rizzo, V. Milana and G. Gambarini. Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study The Open Dentistry Journal 2009;3:55-58
  21. Kim HC, Yum J, Hur B, Cheung GSP. Cyclic fatigue and fracture characteristics of ground and twisted nickel-titanium rotary files. J Endod 2010;36:147–52.
  22. Rodrigues RCV, Lopes HP, Elias C, et al. Influence of different manufacturing methods on the cyclic fatigue of rotary nickeltitanium endodontic instruments. J Endod 2011;37:1553–7.
  23. López FU, Travessas JA, Fachin E, Fontanella V, Grecca F. Apical transportation: Two assessment methods. Aust Endod J 2009;35:85-8.
  24. Sidney GB, Batista A, Melo LL. The radiographic platform: A newmethod to evaluate root canal preparation in vitro. J Endod 1991;17:570-2.
  25. Tasdemir T, Aydemir H, Inan U, Unal O. Canal preparation with Hero 642 rotary Ni-Tiinstruments compared with stainless steel hand K-file assessed using computed tomography. Int Endod J 2005;38:402– 8.
  26. Hülsmann M, Gressmann G, Schäfers F. A comparative study of root canal preparationusing Flex Master and HERO 642 rotary Ni-Ti instruments. Int Endod J 2003;36:358–66.
  27. Peters OA, Schönenberger K, Laib A. Effects of four Ni-Ti preparation techniques on root canal geometry assessed by micro computed tomography. Int Endod J 2001;34:221–30.
  28. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod 2000;26:210–6.
  29. Fernando Duran-Sindreu, Marc Garcia, Juan Gonzalo Olivieri, Montse Mercade, Sergio Morello and Miguel Roig. A Comparison of Apical Transportation between Flex Master and Twisted Files Rotary Instruments. J Endod 2012;38:993-989
  30. Laila Gonzales Freire, Giulio Gavini, Fernando Branco- Barletta, Rodrigo Sanches-Cunha and Marcelo dos Santos. Microscopic computerized tomographic evaluation of root canal transportation prepared with twisted or ground nickeltitanium rotary instruments. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;112:e143-e148
  31. Mateus Silveira Martins hartmann, Vania regina camargo fontanella, José roberto vanni; Volmir joao fornaril Fernando Branco. CT Evaluation of Apical Canal Transportation Associated with Stainless Steel Hand Files, Oscillatory Technique and ProTaper Rotary System. Braz Dent J 2011; 22(4): 288-93
  32. Marc Garcýa, Fernando Duran-Sindreu, Montse Mercade, Rufino Bueno, and Miguel Roig. A Comparison of Apical Transportation between ProFile and RaCe Rotary Instruments. J Endod 2012; 38:990-992
  33. Ricardo Castello Escriv, Teresa Alegre-Domingo, Vicente Faus-Matoses, Sophie Roman-Richon and Vicente J. Faus- Llacer. In Vitro Comparison of Cyclic Fatigue Resistance of ProTaper, Wave One, and Twisted Files. J Endod 2012;38:1521–1524
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.